<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
		>
<channel>
	<title>Comments on: Gator Clone</title>
	<atom:link href="http://gaussmarkov.net/wordpress/circuits/gator-clone/feed/" rel="self" type="application/rss+xml" />
	<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/</link>
	<description>guitar stompboxes and electronics</description>
	<lastBuildDate>Fri, 03 Feb 2012 03:55:27 -0700</lastBuildDate>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1</generator>
	<item>
		<title>By: seifhesham</title>
		<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/comment-page-1/#comment-1545</link>
		<dc:creator>seifhesham</dc:creator>
		<pubDate>Sat, 13 Aug 2011 01:02:43 +0000</pubDate>
		<guid isPermaLink="false">http://gaussmarkov.net/wordpress/circuits/gator-clone/#comment-1545</guid>
		<description>no coment  thank you</description>
		<content:encoded><![CDATA[<p>no coment  thank you</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: seifhesham</title>
		<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/comment-page-1/#comment-1544</link>
		<dc:creator>seifhesham</dc:creator>
		<pubDate>Sat, 13 Aug 2011 01:01:45 +0000</pubDate>
		<guid isPermaLink="false">http://gaussmarkov.net/wordpress/circuits/gator-clone/#comment-1544</guid>
		<description>no coment</description>
		<content:encoded><![CDATA[<p>no coment</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Edwin</title>
		<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/comment-page-1/#comment-1490</link>
		<dc:creator>Edwin</dc:creator>
		<pubDate>Thu, 03 Mar 2011 21:03:28 +0000</pubDate>
		<guid isPermaLink="false">http://gaussmarkov.net/wordpress/circuits/gator-clone/#comment-1490</guid>
		<description>Cant you replace the lm3080 for a tl072 or some similar operational ic, removing the level pot?

Greetings from Colombia.</description>
		<content:encoded><![CDATA[<p>Cant you replace the lm3080 for a tl072 or some similar operational ic, removing the level pot?</p>
<p>Greetings from Colombia.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Ariel</title>
		<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/comment-page-1/#comment-1279</link>
		<dc:creator>Ariel</dc:creator>
		<pubDate>Tue, 26 Jan 2010 15:54:14 +0000</pubDate>
		<guid isPermaLink="false">http://gaussmarkov.net/wordpress/circuits/gator-clone/#comment-1279</guid>
		<description>Hola Hammer !!! 

Como hiciste para que te funcione ??
Estoy renegando hace bastante jeje 

un abrazo</description>
		<content:encoded><![CDATA[<p>Hola Hammer !!! </p>
<p>Como hiciste para que te funcione ??<br />
Estoy renegando hace bastante jeje </p>
<p>un abrazo</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Hammer</title>
		<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/comment-page-1/#comment-1205</link>
		<dc:creator>Hammer</dc:creator>
		<pubDate>Sun, 11 Oct 2009 22:19:39 +0000</pubDate>
		<guid isPermaLink="false">http://gaussmarkov.net/wordpress/circuits/gator-clone/#comment-1205</guid>
		<description>A usefull gate and volume swell pedal. Not noisy except a little hiss in high level settings when the sound decays. I&#039;ve used a LM308 as IC1 until change that one for TL081, whithout differences in the general performace.
Another mod&#039;s on my built:
Level pot:  100k
treshold pot: 25 k 
No trigger connection and no temporary switch.

REGARDS FROM ARGENTINA !!!</description>
		<content:encoded><![CDATA[<p>A usefull gate and volume swell pedal. Not noisy except a little hiss in high level settings when the sound decays. I&#8217;ve used a LM308 as IC1 until change that one for TL081, whithout differences in the general performace.<br />
Another mod&#8217;s on my built:<br />
Level pot:  100k<br />
treshold pot: 25 k<br />
No trigger connection and no temporary switch.</p>
<p>REGARDS FROM ARGENTINA !!!</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: anonym</title>
		<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/comment-page-1/#comment-1200</link>
		<dc:creator>anonym</dc:creator>
		<pubDate>Thu, 01 Oct 2009 16:24:33 +0000</pubDate>
		<guid isPermaLink="false">http://gaussmarkov.net/wordpress/circuits/gator-clone/#comment-1200</guid>
		<description>Is there sound samples?</description>
		<content:encoded><![CDATA[<p>Is there sound samples?</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Steve</title>
		<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/comment-page-1/#comment-1159</link>
		<dc:creator>Steve</dc:creator>
		<pubDate>Tue, 30 Jun 2009 12:40:34 +0000</pubDate>
		<guid isPermaLink="false">http://gaussmarkov.net/wordpress/circuits/gator-clone/#comment-1159</guid>
		<description>What exactly does the momentary switch do?</description>
		<content:encoded><![CDATA[<p>What exactly does the momentary switch do?</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: jazzmaster</title>
		<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/comment-page-1/#comment-950</link>
		<dc:creator>jazzmaster</dc:creator>
		<pubDate>Sat, 25 Oct 2008 10:52:54 +0000</pubDate>
		<guid isPermaLink="false">http://gaussmarkov.net/wordpress/circuits/gator-clone/#comment-950</guid>
		<description>Hi gaussmarkov,
nice project you made here, big thx.
i i finished it this week, and the effect is much better than in SG! much longer attack delay, nice exactly what i was looking for. 
had to sub some parts, 
- 500nF cap -&gt; 470nF+47nF in parallel
- LM3080 -&gt; CA 3080E

but there are some minus too, it plopps like hell when done by schematic when u hit the bypass switch! ive added a output cap and a pulldown resistor to test, 100nF/10M no plopp after that :)
then ive changed em to better values for having not a to big output impendance 1uF/100K. just wanted to test it, but by mistake i plugged amp into trigger jack, now nothing is working anymore, pretty strange. changed the TL072&#039;s and the LM308N, dont have a spare here for the CA3080, but i will get soon some LM3080. also treshold was working a bit strange, i was only able set this between 07h and 09h, if i opened the pot more, no more effect. thats normal? maybe thats a CA/LM 3080 issue, i will see when i got the LM here. will check with audioprobe later where the fox hides.</description>
		<content:encoded><![CDATA[<p>Hi gaussmarkov,<br />
nice project you made here, big thx.<br />
i i finished it this week, and the effect is much better than in SG! much longer attack delay, nice exactly what i was looking for.<br />
had to sub some parts,<br />
- 500nF cap -&gt; 470nF+47nF in parallel<br />
- LM3080 -&gt; CA 3080E</p>
<p>but there are some minus too, it plopps like hell when done by schematic when u hit the bypass switch! ive added a output cap and a pulldown resistor to test, 100nF/10M no plopp after that <img src='http://gaussmarkov.net/wordpress/wp-includes/images/smilies/icon_smile.gif' alt=':)' class='wp-smiley' /><br />
then ive changed em to better values for having not a to big output impendance 1uF/100K. just wanted to test it, but by mistake i plugged amp into trigger jack, now nothing is working anymore, pretty strange. changed the TL072&#8242;s and the LM308N, dont have a spare here for the CA3080, but i will get soon some LM3080. also treshold was working a bit strange, i was only able set this between 07h and 09h, if i opened the pot more, no more effect. thats normal? maybe thats a CA/LM 3080 issue, i will see when i got the LM here. will check with audioprobe later where the fox hides.</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: the recluse</title>
		<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/comment-page-1/#comment-846</link>
		<dc:creator>the recluse</dc:creator>
		<pubDate>Fri, 04 Jul 2008 17:57:30 +0000</pubDate>
		<guid isPermaLink="false">http://gaussmarkov.net/wordpress/circuits/gator-clone/#comment-846</guid>
		<description>The parts list asks for a momentary switch.  What is this used for?  Is it the bypass switch, or does it provide some optional function?</description>
		<content:encoded><![CDATA[<p>The parts list asks for a momentary switch.  What is this used for?  Is it the bypass switch, or does it provide some optional function?</p>
]]></content:encoded>
	</item>
	<item>
		<title>By: Ananan</title>
		<link>http://gaussmarkov.net/wordpress/circuits/gator-clone/comment-page-1/#comment-213</link>
		<dc:creator>Ananan</dc:creator>
		<pubDate>Mon, 03 Dec 2007 18:17:10 +0000</pubDate>
		<guid isPermaLink="false">http://gaussmarkov.net/wordpress/circuits/gator-clone/#comment-213</guid>
		<description>Here now all in the full order!... And nobody will set questions! Thanks!</description>
		<content:encoded><![CDATA[<p>Here now all in the full order!&#8230; And nobody will set questions! Thanks!</p>
]]></content:encoded>
	</item>
</channel>
</rss>

